• Gossen Metrawatt

Characteristic Values

Z3512A WZ12C CP330 METRAFLEX P300 WZ12A Z3512 CP30 Z3511 METRAFLEX 300M CP1800 WZ12D WZ11B WZ11A WZ1001 CP1100 WZ12B METRAFLEX 3000
Item number Z225A Z219C Z202B Z502E Z219A GTZ3512000R0001 Z201B GTZ3511000R0001 Z207M Z204A Z219D Z208B Z208A Z194A Z203B Z219B Z207E
Product details page Details Details Details Details Details Details Details Details Details Details Details Details Details Details Details Details Details
Continuity test
Max. voltage measuring circuit category 600Volt 300Volt 300Volt 600Volt 300Volt 600Volt 300Volt 600Volt 600Volt 300Volt 300Volt 600Volt 600Volt 600Volt 300Volt 300Volt 600Volt
Diode test
Transmission factor mV/A 1
10
100
1000
1
1000
1
10
100 10
100
1000
1
10
1
10
1
10
100 1
10
100
Frequency range alternating current 10Hertz - 3000Hertz 45Hertz - 400Hertz 0Hertz - 20000Hertz 20Hertz - 4000Hertz 45Hertz - 400Hertz 30Hertz - 5000Hertz 0Hertz - 20000Hertz 45Hertz - 1000Hertz 20Hertz - 100000Hertz 0Hertz - 20000Hertz 45Hertz - 500Hertz 30Hertz - 500Hertz 48Hertz - 400Hertz 40Hertz - 1000Hertz 0Hertz - 20000Hertz 45Hertz - 500Hertz 10Hertz - 10000Hertz
Phase sequence determination
Intrinsic uncertainty of the measured value in % 0.2Percentage 2Percentage 1Percentage 1Percentage 3Percentage 0.7Percentage 1Percentage 3Percentage 1Percentage 1Percentage 2.5Percentage 1Percentage 1Percentage 1Percentage 1Percentage 1.5Percentage 1Percentage
Analogue bar graph display
Measuring range selection Manual Manual Manual Manual Manual Manual Manual Manual Manual
Current measuring range, AC 0.001 - 1000 0.001 - 150 0.05 - 300 3 - 300 15 - 180 0.5 - 1000 0.001 - 30 4 - 500 0 - 300 0.1 - 1250 0.03 - 150 0.5 - 200 1 - 200 1 - 1000 0.1 - 1000 0.01 - 100 0.1 - 3000
Type of current AC AC AC/DC AC AC AC AC/DC AC AC AC/DC AC AC AC AC AC/DC AC AC
True RMS measurement x x x x x x x
Voltage measurement, AC
Voltage measurement, DC
Resistance measuring range
Power measuring x
Leakage current measuring
Harmonics measurement x
Measurement in cables with for- and back conductor
Jaw opening 52 15 25 150 15 52 25 30 160 32 15 20 20 43 32 15 610
Version as adapter to connect to multi meter x x x x x x x x x x x x x x
Interface x
Measuring circuit category CAT III CAT III CAT III CAT IV CAT III CAT III CAT III CAT III CAT IV CAT III CAT III CAT III CAT III CAT III CAT III CAT III CAT IV
Intrinsic uncertainty in amps 50Milliampere 10Milliampere 2Milliampere 400Milliampere 100Milliampere 100Milliampere 0.1Milliampere 50Milliampere 500Milliampere 100Milliampere 1Milliampere 100Milliampere
Current measurement range AC+DC 0.001Ampere - 30Ampere 0.1Ampere - 1250Ampere 0.1Ampere - 1000Ampere
Current measuring range, DC 0.001 - 30 0.1 - 1250 0.1 - 1000
Transmission factor mA/A 1 1 1 1 1000
Frequency measuring range for AC currents

Dialogue, Information and Actions: