SECUTEST BASE | SECUTEST PRO | SECUTEST BASE IQ | SECUTEST PRO IQ | SECUTEST S2 N+ | SECUTEST S2 N+10 | SECUTEST SIII+H | SECUTEST SIII+ | |
---|---|---|---|---|---|---|---|---|
Item number | M7050-V001 | M7050-V003 | M705A | M705C | M7010-V031 | M7010-V032 | M7010-V013 | M7010 |
Product details page | Details | Details | Details | Details | Details | Details | Details | Details |
HTML report | x | x | x | x | ||||
Supply voltage | 90Volt - 250Volt | 90Volt - 250Volt | 90Volt - 250Volt | 90Volt - 250Volt | 115Volt - 230Volt | 115Volt - 230Volt | 115Volt - 230Volt | 115Volt - 230Volt |
Printer connection | USB-A | USB-A | USB-A | USB-A | Other | Other | ||
Indication | Graphic | Graphic | Graphic | Graphic | Graphic | Graphic | Graphic | Graphic |
Automatic test sequence | x | x | x | x | x | x | x | x |
Limit value indication | x | x | x | x | x | x | x | x |
Measured value memory | x | x | x | x | x | x | x | x |
Deadlines management | Optional | Optional | Optional | Optional | No | No | No | No |
Active testing | x | x | x | x | x | x | x | x |
Passive testing | x | x | x | x | x | x | x | x |
Protective ground resistance measuring range | 0.001 - 30 | 0 - 30 | 0.001 - 27 | 0 - 27 | 3 - 30 | 0 - 30 | 0 - 30 | 0 - 30 |
Isolation resistance measuring range | 1 - 300 | 0.01 - 300 | 1 - 200 | 0.01 - 200 | 3 - 300 | 0.05 - 300 | 0.05 - 300 | 0.05 - 300 |
Protective conductor current | x | x | x | x | x | x | x | x |
Contact current | x | x | x | x | x | x | x | x |
Differential current method | x | x | x | x | x | x | x | x |
Direct method | x | x | x | x | x | x | x | x |
Alternative method | x | x | x | x | x | x | x | x |
Consumption current measurement | x | x | x | x | x | x | x | x |
Power measuring | x | x | x | x | x | x | x | x |
Voltage measurement | x | x | x | x | x | x | x | x |
Connection for external measuring adapter | x | x | x | x | x | x | x | x |
Testing of extension leads | x | x | x | x | x | x | x | x |
Testing with 2 probes | No | Yes | No | Yes | Optional | Yes | Yes | Yes |
Printer integrated | ||||||||
Suitable for use by an instructed person | x | x | x | x | x | x | x | |
Connection detection | x | x | x | x | x | x | x | x |
DAkkS calibration certificate | x | x | x | x | x | x | x | x |
Import of data | Optional | Yes | Optional | Yes | No | No | No | No |
Integrated rubber protection | x | x | x | x | ||||
Measurement of time to trip of (P)RCDs | x | x | x | x | ||||
Save measurement series | x | x | x | x | ||||
Test current 10A | x | x | x | x | x | |||
remote compatible | Optional | Yes | Optional | Yes | Yes | Yes | Yes | Yes |
Safety class detection | x | x | x | x | x | x | x | x |
Management of location data | Optional | Yes | Optional | Yes | No | No | No | No |
Programmable test sequences | Optional | Yes | Optional | Yes | No | No | No | No |
Frequency of supply voltage | 50Hertz - 400Hertz | 50Hertz - 400Hertz | 50Hertz - 400Hertz | 50Hertz - 400Hertz | 50Hertz - 60Hertz | 50Hertz - 60Hertz | 50Hertz - 60Hertz | 50Hertz - 60Hertz |
Description of RFID | x | x | ||||||
Printing barcodes | x | x | ||||||
Test sequences per VDE 0544-4 (welding equipment) | x | |||||||
Test sequences per IC 62353 (medical devices) | x | x | x | x | ||||
Data transmission to PC via BT/USB | x | |||||||
Test sequences for testing PRCDs | x | |||||||
Documentation software | x | x | x | |||||
Extension for testing and managing medical devices | x | x | x | |||||
CC000739 | Optional | No | No | |||||
Test sequences per IEC 60601 (medical devices) | ||||||||
High-voltage test | 500Volt - 6000Volt | 500Volt - 6000Volt | 500Volt - 6000Volt | |||||
Relocation management for site data (moving test objects) | ||||||||
Type of interface | RS-232 | |||||||
CC115226 | Optional | |||||||
CC115227 | Optional |