• Gossen Metrawatt

Characteristic Values

MAVOWATT 270-400 Mini Flex Paket MAVOWATT 240 TR2510B Paket MAVOWATT 270 Flex Paket MAVOWATT 270 TR2510B Paket MAVOWATT 230 TR2510B Paket MAVOWATT 270 Mini Flex Paket MAVOWATT 230 Mini Flex Paket MAVOWATT 270-400 TR2510B Paket MAVOWATT 240 Mini Flex Paket MAVOWATT 230 Flex Paket MAVOWATT 240 Flex Paket MAVOWATT 270-400 Flex Paket
Item number M820M M820O M820G M820P M820N M820J M820H M820Q M820I M820D M820F M820L
Product details page Details Details Details Details Details Details Details Details Details Details Details Details
Indication Graphic Graphic Graphic Graphic Graphic Graphic Graphic Graphic Graphic Graphic Graphic Graphic
Number of voltage input channels 4 4 4 4 4 4 4 4 4 4 4 4
Number of current input channels 4 4 4 4 4 4 4 4 4 4 4 4
Current measurement With current clamp meter/clamp adapter With current clamp meter/clamp adapter With current clamp meter/clamp adapter With current clamp meter/clamp adapter With current clamp meter/clamp adapter With current clamp meter/clamp adapter With current clamp meter/clamp adapter With current clamp meter/clamp adapter With current clamp meter/clamp adapter With current clamp meter/clamp adapter With current clamp meter/clamp adapter With current clamp meter/clamp adapter
Harmonics measurement x x x x x x x x x x x x
Power factor x x x x x x x x x x x x
Effective power x x x x x x x x x x x x
Reactive power x x x x x x x x x x x x
Apparent power x x x x x x x x x x x x
Step angle (cos phi) x x x x x x x x x x x x
Power/work x x x x x x x x x x x x
Interface x x x x x x x x x x x x
Measured value memory x x x x x x x x x x x x
Current supply Battery (rechargeable)/mains Battery (rechargeable)/mains Battery (rechargeable)/mains Battery (rechargeable)/mains Battery (rechargeable)/mains Battery (rechargeable)/mains Battery (rechargeable)/mains Battery (rechargeable)/mains Battery (rechargeable)/mains Battery (rechargeable)/mains Battery (rechargeable)/mains Battery (rechargeable)/mains
Voltage measuring range/AC direct 0 - 1000 0 - 1000 0 - 1000 0 - 1000 0 - 1000 0 - 1000 0 - 1000 0 - 1000 0 - 1000 0 - 1000 0 - 1000 0 - 1000
Communication Ethernet
Wi-Fi
Bluetooth
USB
VNC for full remote control of the instrument
Apple and Android apps for acquisition and alarm generation
GPS time synch * (see comment)
Ethernet
Wi-Fi
Bluetooth
USB
VNC for full remote control of the instrument
Apple and Android apps for acquisition and alarm generation
GPS time synch * (see comment)
Ethernet
Wi-Fi
Bluetooth
USB
VNC for full remote control of the instrument
Apple and Android apps for acquisition and alarm generation
GPS time synch * (see comment)
Ethernet
Wi-Fi
Bluetooth
USB
VNC for full remote control of the instrument
Apple and Android apps for acquisition and alarm generation
GPS time synch * (see comment)
Ethernet
Bluetooth
VNC for full remote control of the instrument
Apple and Android apps for acquisition and alarm generation
GPS time synch * (see comment)
Ethernet
Wi-Fi
Bluetooth
USB
VNC for full remote control of the instrument
Apple and Android apps for acquisition and alarm generation
GPS time synch * (see comment)
Ethernet
Bluetooth
VNC for full remote control of the instrument
Apple and Android apps for acquisition and alarm generation
GPS time synch * (see comment)
Ethernet
Wi-Fi
Bluetooth
USB
VNC for full remote control of the instrument
Apple and Android apps for acquisition and alarm generation
GPS time synch * (see comment)
Ethernet
Wi-Fi
Bluetooth
USB
VNC for full remote control of the instrument
Apple and Android apps for acquisition and alarm generation
GPS time synch * (see comment)
Ethernet
Bluetooth
VNC for full remote control of the instrument
Apple and Android apps for acquisition and alarm generation
GPS time synch * (see comment)
Ethernet
Wi-Fi
Bluetooth
USB
VNC for full remote control of the instrument
Apple and Android apps for acquisition and alarm generation
GPS time synch * (see comment)
Ethernet
Wi-Fi
Bluetooth
USB
VNC for full remote control of the instrument
Apple and Android apps for acquisition and alarm generation
GPS time synch * (see comment)
Input Differential, voltage channels, 0 to 1000�V�AC/DC Differential, voltage channels, 0 to 1000�V�AC/DC Differential, voltage channels, 0 to 1000�V�AC/DC Differential, voltage channels, 0 to 1000�V�AC/DC Differential, voltage channels, 0 to 1000�V�AC/DC Differential, voltage channels, 0 to 1000�V�AC/DC Differential, voltage channels, 0 to 1000�V�AC/DC Differential, voltage channels, 0 to 1000�V�AC/DC Differential, voltage channels, 0 to 1000�V�AC/DC Differential, voltage channels, 0 to 1000�V�AC/DC Differential, voltage channels, 0 to 1000�V�AC/DC Differential, voltage channels, 0 to 1000�V�AC/DC
Measurement 1000V CAT III, 600V CAT IV
IEC 61000-4-30:2008, class A with certificate
Sampling rate: 512 values/period/channel for U & I
U-I dips and swells
Transients as of 32/40µs (60/50Hz)
Transients as of 1µs
Power demand and energy consumption
IEEE 1459, advanced energy
Harmonics and interharmonics U (127), I (63)
EN 50160, edition 3
400 Hz monitoring
1000V CAT III, 600V CAT IV
IEC 61000-4-30:2008, class A with certificate
Sampling rate: 512 values/period/channel for U & I
U-I dips and swells
Transients as of 32/40µs (60/50Hz)
Power demand and energy consumption
IEEE 1459, advanced energy
Harmonics and interharmonics U (127), I (63)
EN 50160, edition 3
1000V CAT III, 600V CAT IV
IEC 61000-4-30:2008, class A with certificate
Sampling rate: 512 values/period/channel for U & I
U-I dips and swells
Transients as of 32/40µs (60/50Hz)
Transients as of 1µs
Power demand and energy consumption
IEEE 1459, advanced energy
Harmonics and interharmonics U (127), I (63)
EN 50160, edition 3
1000V CAT III, 600V CAT IV
IEC 61000-4-30:2008, class A with certificate
Sampling rate: 512 values/period/channel for U & I
U-I dips and swells
Transients as of 32/40µs (60/50Hz)
Transients as of 1µs
Power demand and energy consumption
IEEE 1459, advanced energy
Harmonics and interharmonics U (127), I (63)
EN 50160, edition 3
1000V CAT III, 600V CAT IV
IEC 61000-4-30:2008, class A with certificate
Sampling rate: 512 values/period/channel for U & I
U-I dips and swells
Transients as of 32/40µs (60/50Hz)
Power demand and energy consumption
Harmonics and interharmonics U (127), I (63)
EN 50160, edition 3
1000V CAT III, 600V CAT IV
IEC 61000-4-30:2008, class A with certificate
Sampling rate: 512 values/period/channel for U & I
U-I dips and swells
Transients as of 32/40µs (60/50Hz)
Transients as of 1µs
Power demand and energy consumption
IEEE 1459, advanced energy
Harmonics and interharmonics U (127), I (63)
EN 50160, edition 3
1000V CAT III, 600V CAT IV
IEC 61000-4-30:2008, class A with certificate
Sampling rate: 512 values/period/channel for U & I
U-I dips and swells
Transients as of 32/40µs (60/50Hz)
Power demand and energy consumption
Harmonics and interharmonics U (127), I (63)
EN 50160, edition 3
1000V CAT III, 600V CAT IV
IEC 61000-4-30:2008, class A with certificate
Sampling rate: 512 values/period/channel for U & I
U-I dips and swells
Transients as of 32/40µs (60/50Hz)
Transients as of 1µs
Power demand and energy consumption
IEEE 1459, advanced energy
Harmonics and interharmonics U (127), I (63)
EN 50160, edition 3
400 Hz monitoring
1000V CAT III, 600V CAT IV
IEC 61000-4-30:2008, class A with certificate
Sampling rate: 512 values/period/channel for U & I
U-I dips and swells
Transients as of 32/40µs (60/50Hz)
Power demand and energy consumption
IEEE 1459, advanced energy
Harmonics and interharmonics U (127), I (63)
EN 50160, edition 3
1000V CAT III, 600V CAT IV
IEC 61000-4-30:2008, class A with certificate
Sampling rate: 512 values/period/channel for U & I
U-I dips and swells
Transients as of 32/40µs (60/50Hz)
Power demand and energy consumption
Harmonics and interharmonics U (127), I (63)
EN 50160, edition 3
1000V CAT III, 600V CAT IV
IEC 61000-4-30:2008, class A with certificate
Sampling rate: 512 values/period/channel for U & I
U-I dips and swells
Transients as of 32/40µs (60/50Hz)
Power demand and energy consumption
IEEE 1459, advanced energy
Harmonics and interharmonics U (127), I (63)
EN 50160, edition 3
1000V CAT III, 600V CAT IV
IEC 61000-4-30:2008, class A with certificate
Sampling rate: 512 values/period/channel for U & I
U-I dips and swells
Transients as of 32/40µs (60/50Hz)
Transients as of 1µs
Power demand and energy consumption
IEEE 1459, advanced energy
Harmonics and interharmonics U (127), I (63)
EN 50160, edition 3
400 Hz monitoring
Answer modules Motor status
Voltage dip direction
Switching of compensation capacitors
Motor status
Voltage dip direction
Switching of compensation capacitors
Motor status
Voltage dip direction
Switching of compensation capacitors
Motor status
Voltage dip direction
Switching of compensation capacitors
Motor status Motor status
Voltage dip direction
Switching of compensation capacitors
Motor status Motor status
Voltage dip direction
Switching of compensation capacitors
Motor status
Voltage dip direction
Switching of compensation capacitors
Motor status Motor status
Voltage dip direction
Switching of compensation capacitors
Motor status
Voltage dip direction
Switching of compensation capacitors
Set-ups Number of transient triggers
Automatic setups for power quality, power demand and energy consumption
Setup wizard
Max. pre/post-trigger periods
Monitoring operating modes
Number of transient triggers
Automatic setups for power quality, power demand and energy consumption
Setup wizard
Max. pre/post-trigger periods
Monitoring operating modes
Number of transient triggers
Automatic setups for power quality, power demand and energy consumption
Setup wizard
Max. pre/post-trigger periods
Monitoring operating modes
Number of transient triggers
Automatic setups for power quality, power demand and energy consumption
Setup wizard
Max. pre/post-trigger periods
Monitoring operating modes
Number of transient triggers
Automatic setups for power quality, power demand and energy consumption
Monitoring operating modes
Setup wizard
Max. pre/post-trigger periods
Number of transient triggers
Automatic setups for power quality, power demand and energy consumption
Setup wizard
Max. pre/post-trigger periods
Monitoring operating modes
Number of transient triggers
Automatic setups for power quality, power demand and energy consumption
Monitoring operating modes
Setup wizard
Max. pre/post-trigger periods
Number of transient triggers
Automatic setups for power quality, power demand and energy consumption
Setup wizard
Max. pre/post-trigger periods
Monitoring operating modes
Number of transient triggers
Automatic setups for power quality, power demand and energy consumption
Setup wizard
Max. pre/post-trigger periods
Monitoring operating modes
Number of transient triggers
Automatic setups for power quality, power demand and energy consumption
Monitoring operating modes
Setup wizard
Max. pre/post-trigger periods
Number of transient triggers
Automatic setups for power quality, power demand and energy consumption
Setup wizard
Max. pre/post-trigger periods
Monitoring operating modes
Number of transient triggers
Automatic setups for power quality, power demand and energy consumption
Setup wizard
Max. pre/post-trigger periods
Monitoring operating modes
Max. pre-/post-trigger periods 100000 100000 100000 100000 100 100000 100 100000 100000 100 100000 100000

Dialogue, Information and Actions: