• Gossen Metrawatt

Characteristic Values

METRALINE DM41 METRAHit WORLD METRAHit 2+ METRALINE DM62 METRALINE DM61
Item number M192A M206A M205A M197A M194A
Product details page Details Details Details Details Details
Display
Indication Digital Digital Analogue/digital Digital Analogue/digital
Indication digits 4000 6000 6000 6600 6600
Multiple display x x
Measuring range selection Manual/automatic Manual/automatic Manual/automatic Manual/automatic Manual/automatic
Basic data
Type of measurement Averaging TRMS TRMS TRMS Averaging
True RMS measurement x x x
Basic accuracy 0.5Percentage 0.5Percentage 0.5Percentage 0.4Percentage 0.4Percentage
Measuring circuit category CAT III CAT IV CAT III CAT IV CAT III
Max. voltage measuring circuit category 600Volt 600Volt 600Volt 600Volt 600Volt
Relative value measurement x x x x x
Min. value storage x x x x x
Max. value storage x x x x x
Peak value memory x x
Data hold x x x x x
Special functions
Explosion-tested version
Power and energy measurement
Harmonics analysis/power quality
Crest factor measurement
Rotational speed measuring x
Duty cycle measurements x x x
Pulse freqency measurement MHz @ 5V TTL
Inductance measurement
Interturn short-circuit high-voltage test
Automatic circuit breaker
Voltage measurement
Voltage measurement types DC
AC
DC
AC
DC
AC
DC
AC
DC
AC
With decibel measurement (dB)
Voltage measuring range DC 0.0001Volt - 600Volt 0.0001Volt - 1000Volt 0.0001Volt - 600Volt 0.0001Volt - 1000Volt 0.0001Volt - 1000Volt
Voltage measuring ranges DC 600 V
400 mV
4 V
40 V
400 V
600 mV
6 V
60 V
600 V
1000 V
600 mV
6 V
60 V
600 V
600 mV
6 V
60 V
600 V
1000 V
600 mV
6 V
60 V
600 V
1000 V
Max. voltage measuring range, DC 600Volt 1000Volt 600Volt 1000Volt 1000Volt
Lowest resolution, DC voltage 0.1 mV 0.1 mV Other 0.1 mV 0.1 mV
Internal resistance volt DC 11
20
10
10
5,2
5
10
5,2
5
11
10
100
11
10
100
Voltage measuring range AC 0.0001Volt - 600Volt 0.0001Volt - 1000Volt 0.0001Volt - 600Volt 0.0001Volt - 1000Volt 0.0001Volt - 1000Volt
Voltage measuring ranges AC 600 V
400 mV
4 V
40 V
400 V
600 mV
6 V
60 V
600 V
1000 V
600 mV
6 V
60 V
600 V
600 mV
6 V
60 V
600 V
1000 V
600 mV
6 V
60 V
600 V
1000 V
Max. voltage measuring range, AC 1000Volt 1000Volt 600Volt 1000Volt 1000Volt
Lowest resolution, AC voltage 0.1 mV 0.1 mV 0.1 mV 0.1 mV 0.1 mV
Frequency range volt AC 20Hertz - 1000Hertz 30Hertz - 800Hertz 30Hertz - 800Hertz 20Hertz - 2000Hertz 20Hertz - 2000Hertz
Internal resistance volt AC 10
11
8,1
4,6
4,4
8,1
4,6
4,4
10
11
100
10
11
100
Current measurement
Current measurement types DC
AC
DC
AC
DC
AC
DC
AC
DC
AC
Current measurement range DC 0,00001Ampere - 10Ampere 0,00001Ampere - 10Ampere 0,00001Ampere - 10Ampere 0,00001Ampere - 10Ampere 0.00001Ampere - 0.66Ampere
Current measuring ranges DC 10:00 AM
40 mA
400 mA
60 mA
600 mA
6:00 AM
10:00 AM
60 mA
600 mA
6:00 AM
10:00 AM
60 mA
600 mA
10:00 AM
60 mA
600 mA
Max. current measuring range, DC 10Ampere 10Ampere 10Ampere 10Ampere 0.66Ampere
Lowest resolution, DC current 10 µA 10 µA 10 µA 10 µA 10 µA
Current measurement range AC 0,00001Ampere - 10Ampere 0,00001Ampere - 10Ampere 0,00001Ampere - 10Ampere 0,00001Ampere - 10Ampere 0.00001Ampere - 0.66Ampere
Current measuring ranges AC 10:00 AM
40 mA
400 mA
60 mA
600 mA
6:00 AM
10:00 AM
60 mA
600 mA
6:00 AM
10:00 AM
60 mA
600 mA
10:00 AM
60 mA
600 mA
Max. current measuring range, AC 10Ampere 10Ampere 10Ampere 10Ampere 0.66Ampere
Lowest resolution, AC current 10 µA 10 µA 10 µA 10 µA 10 µA
Frequency range alternating current 50Hertz - 1000Hertz 30Hertz - 1000Hertz 30Hertz - 1000Hertz 50Hertz - 2000Hertz 50Hertz - 2000Hertz
Current sensor with clipping
Current transformer with clipping x
Resistance measurement
Milliohm measurement with 4 wire technique (Kelvin connection)
Resistance test/diode test x x x x x
Continuity test x x x x x
With conductivity measurement
Resistance measurement range 0.1Ohm - 40000000Ohm 0.1Ohm - 40000000Ohm 0.1Ohm - 40000000Ohm 0.1Ohm - 66000000Ohm 0.1Ohm - 66000000Ohm
Resistance measurement ranges 40 M
400
4 k
40 k
400 k
4 M
600
6 k
60 k
600 k
6 M
40 M
600
6 k
60 k
600 k
6 M
40 M
600
6 k
60 k
600 k
6 M
60 m
600
6 k
60 k
600 k
6 M
60 m
Max. resistance measuring range 40Mega-Ohm 40Mega-Ohm 40Mega-Ohm 66Mega-Ohm 66Mega-Ohm
Lowest resolution, resistance 0.1 Ohm 0.1 Ohm 0.1 Ohm 0.1 Ohm 0.1 Ohm
Nominal test voltage 10 V
Nominal test voltage 50 V
Nominal test voltage 100 V
Nominal test voltage 250 V
Nominal test voltage 500 V
Nominal test voltage 1000 V
Capacitance measurement
Capacitance measurement x x x
Capacitance measuring range 0.000001Mikro-Farad - 200Mikro-Farad 0,00001Mikro-Farad - 400Mikro-Farad 0.000001Mikro-Farad - 40000Mikro-Farad
Max. capacitance measuring range 200Mikro-Farad 400Mikro-Farad 40000Mikro-Farad
Lowest resolution, capacitance Other 0.00001 µF Other
Cable length measurement
Cable symmetry testing for two wire connections a-b-E
Frequency measurement
Frequency measurement x x x x
Measuring range for frequency 0.000001kiloHertz - 500kiloHertz 0.0001kiloHertz - 1000kiloHertz 0.0001kiloHertz - 1kiloHertz 0,00001.00001kiloHertz - 10000kiloHertz
Max. frequency measuring range 500kiloHertz 1000kiloHertz 1kiloHertz 10000kiloHertz
Lowest resolution, frequency 0.001 Hz 0.1 Hz 0.1 Hz 0.01 Hz
Temperature measurement
Temperature measurement x x x x x
Temperature measurement TC x x x x x
Temperature measuring range TC -50Degrees celsius - 1300Degrees celsius -50Degrees celsius - 800Degrees celsius -50Degrees celsius - 400Degrees celsius -50Degrees celsius - 1300Degrees celsius -50Degrees celsius - 1300Degrees celsius
Temperature measurement RTD
Max. temperature measuring range 1300Degrees celsius 800Degrees celsius 400Degrees celsius 1300Degrees celsius 1300Degrees celsius
Lowest resolution temperature 1 °C 0.1 °C 0.1 °C 1 °C 1 °C
Interface x
Bluetooth interface
IR interface x
Measured value memory
Miscellaneous
Power supply unit socket
Capacitance measurement ranges 600µF
60 nF
600 nF
6 �F
60 �F
6.6 mF
40 mF
Current measuring range with current transformers
Clip factors

Dialogue, Information and Actions: