• Gossen Metrawatt

Characteristic Values

Starterpaket TECH+ IQ Starterpaket XTRA IQ Meisterpaket XTRA IQ MEDpaket XTRA IQ Profipaket XTRA IQ Meisterpaket TECH+ IQ Starterpaket XTRA IQ Meisterpaket XTRA IQ Profipaket XTRA IQ Starterpaket TECH+ IQ Meisterpaket TECH+ IQ MEDpaket XTRA IQ
Item number M536A M536C M536D M536E M536F M536G M536K M536L M536M M536N M536P M536T
Product details page Details Details Details Details Details Details Details Details Details Details Details Details
Indication Digital Digital Digital Digital Digital Digital Digital Digital Digital Digital Digital Digital
Limit value indication x x x x x x x x x x x x
Status display of internal memory x x x x x x x x x x x x
Measurement functions selectable via rotary switch x x x x x x x x x x x x
Structured measured value memory x x x x x x x x x x x x
Editable menus x x x x x x x x x x x x
Name of inspector editable at test instrument x x x x x x x x x x x x
Creation of test procedures x x x x x x x x x x x x
Help function with connection diagrams x x x x x x x x x x x x
Bluetooth interface x x x x x x x
Interface x x x x x x x x x x x x
Bidirectional data exchange x x x x x x x x x x x x
Updateable x x x x x x x x x x x x
PE detection by means of finger contact x x x x x x x x x x x x
Automatic measurement cable compensation x x x x x x x x x x x x
Offset management
Connection for test probe with remote triggering
Remote control for testing device x x x x x x x x x x x x
Measurement category CAT IV 300 V
CAT III 600 V
CAT IV 300 V
CAT III 600 V
CAT IV 300 V
CAT III 600 V
CAT IV 300 V
CAT III 600 V
CAT IV 300 V
CAT III 600 V
CAT IV 300 V
CAT III 600 V
CAT IV 300 V
CAT III 600 V
CAT IV 300 V
CAT III 600 V
CAT IV 300 V
CAT III 600 V
CAT IV 300 V
CAT III 600 V
CAT IV 300 V
CAT III 600 V
CAT IV 300 V
CAT III 600 V
Voltage measurement U L-N-PE U L-PE
U N-PE
U L-N
U L-N
U L-PE
U N-PE
U L-N
U L-PE
U N-PE
U L-N
U L-PE
U N-PE
U L-N
U L-PE
U N-PE
U L-PE
U N-PE
U L-N
U L-N
U L-PE
U N-PE
U L-N
U L-PE
U N-PE
U L-N
U L-PE
U N-PE
U L-PE
U N-PE
U L-N
U L-PE
U N-PE
U L-N
U L-N
U L-PE
U N-PE
Phase sequence determination x x x x x x x x x x x x
Low resistance measurement 200 mA 200 mA 200 mA 200 mA 200 mA 200 mA 200 mA 200 mA 200 mA 200 mA 200 mA 200 mA
Low resistance measurement with ramp function x x x x x x x x x x x x
Isolation resistance measurement x x x x x x x x x x x x
Isolation resistance measurement with ramp function x x x x x x x x x x x x
Resistances of isolating floors and walls x x x x x x x x x x x x
Over voltage protector testing x x x x x x x x x x x x
Measurement of standing-surface insulation x x x x x x x x x x x x
Loop resistance/impedance measurement x x x x x x x x x x x x
Loop measurement without RCD/FI release x x x x x x x x x x x x
Detection short-circuit current/overcurrent protection x x x x x x x x x x x x
Testing of IT networks 500 V 500 V 500 V 500 V 500 V 500 V 500 V 500 V 500 V 500 V 500 V 500 V
Mains internal resistance measurement x x x x x x x x x x x x
Voltage drop measurement x x x x x x x x x x x x
Earthing measurement x x x x x x x x
Earth resistance measurement mains powered Selective measurement / 3-pole measurement with probe and current clamp sensor
3-pole measurement with probe
2-pole measurement
2-pole measurement
3-pole measurement with probe
Selective measurement / 3-pole measurement with probe and current clamp sensor
2-pole measurement
3-pole measurement with probe
Selective measurement / 3-pole measurement with probe and current clamp sensor
2-pole measurement
3-pole measurement with probe
Selective measurement / 3-pole measurement with probe and current clamp sensor
2-pole measurement
3-pole measurement with probe
Selective measurement / 3-pole measurement with probe and current clamp sensor
Selective measurement / 3-pole measurement with probe and current clamp sensor
3-pole measurement with probe
2-pole measurement
2-pole measurement
3-pole measurement with probe
Selective measurement / 3-pole measurement with probe and current clamp sensor
2-pole measurement
3-pole measurement with probe
Selective measurement / 3-pole measurement with probe and current clamp sensor
2-pole measurement
3-pole measurement with probe
Selective measurement / 3-pole measurement with probe and current clamp sensor
Selective measurement / 3-pole measurement with probe and current clamp sensor
3-pole measurement with probe
2-pole measurement
Selective measurement / 3-pole measurement with probe and current clamp sensor
3-pole measurement with probe
2-pole measurement
2-pole measurement
3-pole measurement with probe
Selective measurement / 3-pole measurement with probe and current clamp sensor
Selective grounding measurement x x x x x x x x x x x x
Earth loop measurement x x x x x x x x
Specific grounding measurement x x x x x x x x
RCD/FI testing x x x x x x x x x x x x
RCD/FI testing with rising residual current x x x x x x x x x x x x
RCD tripping test with nominal residual current x x x x x x x x x x x x
RCD/FI analysis function x x x x x x x x x x x x
RCD tripping test with nominal residual current and simultaneously rising residual current x x x x x x x x x x x x
PRCD testing type S, type K x x x x x x x x x x x x
Testing of motor protection switch x x x x x x x x x x x x
Testing of IMDs and RCMs x x x x x x x x
Testing of charging devices E-Mobility, simulation of vehicle status x x x x x x x x x x x x
Measuring of leakage currents with adapter x x x x x x x x
Measurement of touch current
Measurement of residual voltage x x x x x x x x
Connection of barcode or RFID reader x x x x x x x x x x x x
Connection for current clamp sensors x x x x x x x x x x x x
Connection of temperature and humidity sensor
Connection of earth spikes x x x x x x x x
Earth resistance measurement battery powered 3-pole measurement / 4-pole measurement
Selective measurement with clamp meter / 4-pole measurement
2-clamp measurement
Resistivity
3-pole measurement / 4-pole measurement
Selective measurement with clamp meter / 4-pole measurement
2-clamp measurement
Resistivity
3-pole measurement / 4-pole measurement
Selective measurement with clamp meter / 4-pole measurement
2-clamp measurement
Resistivity
3-pole measurement / 4-pole measurement
Selective measurement with clamp meter / 4-pole measurement
2-clamp measurement
Resistivity
3-pole measurement / 4-pole measurement
Selective measurement with clamp meter / 4-pole measurement
2-clamp measurement
Resistivity
3-pole measurement / 4-pole measurement
Selective measurement with clamp meter / 4-pole measurement
2-clamp measurement
Resistivity
3-pole measurement / 4-pole measurement
Selective measurement with clamp meter / 4-pole measurement
2-clamp measurement
Resistivity

Dialogue, Information and Actions: