Test Instrument with Antimicrobial Properties for Standards-Compliant Testing of the Electrical Safety of Electrical Medical Equipment, Including High-Voltage Test with up to 6 kV DC

The SECULIFE ST PRIME features all of the measuring and test functions required for standards-compliant testing of the effectiveness of protective measures for electrical medical equipment. In addition to the relevant measuring functions for testing electrical safety, the SECULIFE ST PRIME also features a 6 kV DC high-voltage test.
  • Test Instrument with Antimicrobial Properties for Standards-Compliant Testing of the Electrical Safety of Electrical Medical Equipment, Including High-Voltage Test with up to 6 kV DC

With its integrated HV test function, the test instrument can be used during the production of electrical medical devices. The purpose of the high-voltage test is to verify the insulation capacity of the DUT. As a result, air and creepage distances are checked for correct configuration and potential faults in the manufacturing process are detected. Compact and easy to use, with integrated, preconfigured test sequences, the SECULIFE ST PRIME makes work easier for the electrician. With a 10-year service guarantee and a diverse range of test functions, the new safety tester is distinguished by its uncompromising quality and future-proof design.

Product Highlights

  • High-voltage test with up to 6 kV DC
  • Test instrument surfaces feature antimicrobial properties
  • Automated user guidance
  • Protective conductor test, 200 mA AC/DC and 25 A AC
  • 10 configurable terminals (4mm) for applied parts with switching functionality
  • Automatic test sequences according to IEC 61010
  • High-resolution, 4.3" color TFT display
  • Touchscreen
  • USB ports for data input and data transfer
  • Remote control possible via PC (IZYTRONIQ)
  • Integrated data storage for up to 50,000 objects

Your advantages

  • Quick access to the measuring and test functions via rotary switch and softkeys
  • As a compact device including surfaces with antimicrobial properties, it’s ideal for use in medical and healthcare settings.
  • The multiple measurements option permits convenient documentation of several measuring points.
  • Integrated test sequences facilitate quick testing of operating equipment.

Applications

  • Medical electrical equipment – Part 1: General requirements for safety including essential characteristics of DIN VDE 0750-1 (IEC 60601-1)
  • Testing of medical electrical devices in accordance with DIN VDE 0751-1 (IEC/EN 62353)
  • Testing of electrical devices in accordance with DIN VDE 0701 (EN 50678) / 0702 (EN 50699), including extension cords and PRCDs
  • Testing of arc welding equipment in accordance with DIN VDE 0544-4 (IEC/EN 60974-4)
  • Audio, video and information technology equipment, IEC 62911 * Testing of audio/video, information and communication technology equipment, IEC 62368*
  • Routine testing of electrical operating equipment with regard to:
    Medical electrical equipment – Part 1: General requirements for safety including essential characteristics of DIN VDE 0750-1 (IEC 60601-1) *
    * Test sequences with integrated high-voltage testing in preparation

    Safety requirements for electrical equipment for measurement, control and laboratory use, IEC 61010 *
    Safety of electrical equipment for household use, IEC 60335 *
    IEC 61010 and IEC 60335 only with fee-based firmware activation (feature KA03)
    * Sequences with integrated high-voltage testing in preparation
  • Technical characteristics
    • High-voltage test with up to 6 kV DC
    • Protective conductor resistance measurement, 200 mA AC/DC and 25 A AC Insulation resistance measurement
    • 10 configurable 4 mm ports for applied parts
    • Leakage current measurements: protective conductor current, touch current, device leakage current, patient leakage current, leakage current from the applied part
    • Measuring method: direct measurement, differential current measurement, equivalent leakage current (alternative method)
    • Voltage measurement: SELV and PELV
    • Measurement of time to trip for PRCDs
    • Functions test (U, I, P, S, LF, f)
    • Conductor test using test adapters: continuity, short-circuit, polarity (reversed wires)
    • Mains connection and test socket with earthing contact
    • Database expansion DB+
    • Bluetooth (optional)
    • Antimicrobial housing
    • Protection category I per EN 61140
    • Measuring category: 300 V CAT II